Title: An evaluation of computerised tomography (CT) based treatment planning versus digitised image planning (standard planning technique) for carcinoma of the breast, using the four field breast technique
Authors: Govender, Yoguvathie 
Keywords: Tomography
Issue Date: 2007
Abstract: 
Aim/research questions
The aim of the study was to evaluate CT-based treatment planning versus
digitised image planning (standard planning technique) for carcinoma of the
breast, using the four-field breast technique, in terms of the depth of
supraclavicular and axillary nodes, the variability of the breast tissue and the
dose inhomogeneity at the matchline.
The variability of the depth of supraclavicular and axillary nodes has not been
documented in any local or national studies. When simulating patients for
treatment, it is evident that the anatomical variability of patient chest wall
thickness, shape and size is a contributing factor towards the final treatment
plan and dose distribution achieved. Therefore knowing the correct depth of
the nodes and being able to clearly demarcate the breast tissue should result
in a favourable dose administration.
The following questions were addressed:
 What is the dose to the supraclavicular nodes from both plans?
 What is the dose to the axillary nodes from both plans?
 How do the plans differ in terms of dose coverage to the
supraclavicular and axillary nodes?
 What is the relationship between the depth of the supraclavicular
nodes and the patient separation?
ii
 What is the relationship between the depth of the axillary nodes and
the patient separation?
 Does the target volume receive adequate dose coverage from the
plans?
 How is dose to the heart volume affected by target coverage on
both plans?
 How is dose to the lung volume affected by target coverage on both
plans?
 What is the dose variability along the matchline?
 Are the plans over dosing?
 Are the plans under dosing?
Description: 
Submitted in fulfillment of Masters in Radiography, Durban University of Technology, Durban, South Africa, 2007.
URI: http://hdl.handle.net/10321/123
DOI: https://doi.org/10.51415/10321/123
Appears in Collections:Theses and dissertations (Health Sciences)

Files in This Item:
File Description SizeFormat
Govender_2007.pdf5.57 MBAdobe PDFThumbnail
View/Open
Show full item record

Page view(s) 50

1,043
checked on Dec 22, 2024

Download(s) 50

662
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.