Please use this identifier to cite or link to this item: https://hdl.handle.net/10321/3448
DC FieldValueLanguage
dc.contributor.authorTaiwo, Ogunboyo Patricken_US
dc.contributor.authorTiako, Remyen_US
dc.contributor.authorDavidson, Innocent E.en_US
dc.contributor.editorOkafor, K.C.-
dc.contributor.editorAtimati, E.E.-
dc.contributor.editorAchumba,, I.E.-
dc.date.accessioned2020-08-12T06:32:35Z-
dc.date.available2020-08-12T06:32:35Z-
dc.date.issued2017-11-
dc.identifier.citationTaiwo, O. P., Tiako, R. and Davidson, I.E. 2017. Investigation of voltage unbalance in low voltage electric power distribution network under steady state mode. 2017 IEEE 3rd International Conference on Electro-Technology for National Development (NIGERCON). Presented at: 2017 IEEE 3rd International Conference on Electro-Technology for National Development (NIGERCON). 2018-January: 932-939. doi:10.1109/nigercon.2017.8281959en_US
dc.identifier.isbn978-1-5090-6422-9-
dc.identifier.urihttp://hdl.handle.net/10321/3448-
dc.description.abstract© 2017 IEEE. With the ever increasing use of semiconductor devices and information technology (ICT) equipment in the industry's, homes and offices voltage quality are gaining meaningful attention to both industry and the electric utility. Poor voltage quality cause unusually large economic losses all over the world, since voltage quality problem is one of the major power quality disturbances. This report provides an investigative study on the typical 11/0.4 kV, low voltage electric power distribution network. The network was modelled with standard network parameters for low voltage typical electric power distribution network using MATLAB/Simulink Sim Power System tool box. Results obtained from simulation with distribution feeder length 0.5 km for unbalanced 3-phase loads are within the acceptable nominal voltage tolerance range of ± 5 % of the nominal voltage value at the customer's terminal. While this is admissible for customers close to the infeed terminal, it was established that an inadmissible poor voltage reaches the customers at the end of the distribution network for network lengths 0.8 km to 5 km. Voltages measured here were less than the standard allowable limit of 0.95 p.u, of nominal voltage value. The summary of the paper gives recommendations on effective methods for enhancing voltage profile and correcting the unbalanced voltage to an allowable standard.en_US
dc.description.sponsorshipThis research has been supported by Eskom Power Plant Engineering Institute (EPPEI), and The University of KwaZulu-Natal, Durban, South Africa.en_US
dc.format.extent8 pen_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartof2017 IEEE 3rd International Conference on Electro-Technology for National Development (NIGERCON)en_US
dc.subjectLow voltageen_US
dc.subjectVoltage unbalanceen_US
dc.subjectVoltage profileen_US
dc.subjectVoltage qualityen_US
dc.subjectDistribution networksen_US
dc.subjectPower systemen_US
dc.titleInvestigation of voltage unbalance in low voltage electric power distribution network under steady state modeen_US
dc.typeConferenceen_US
dc.date.updated2020-07-29T10:43:26Z-
dc.relation.conference2017 IEEE 3rd International Conference on Electro-Technology for National Development (NIGERCON)en_US
dc.identifier.doi10.1109/nigercon.2017.8281959-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeConference-
Appears in Collections:Research Publications (Engineering and Built Environment)
Files in This Item:
File Description SizeFormat
IED-CP-38-IEEE Nigercon PE_127(939).pdfAccepted version605.63 kBAdobe PDFView/Open
Show simple item record

Page view(s)

484
checked on Dec 22, 2024

Download(s)

348
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.