Please use this identifier to cite or link to this item: https://hdl.handle.net/10321/3848
Title: Shear wave ultrasound elastography of the shoulder joint tendons
Authors: Ramdev, Harashalata 
Issue Date: 10-Jun-2020
Abstract: 
Background: The assessment of tissue elasticity in clinical practice has not been well
established. Shear wave ultrasound elastography is a recent technique which quantitatively
estimates tissue elasticity. This study, therefore, aimed to assess the biomechanics of the
rotator cuff and biceps tendons of the shoulder joint in asymptomatic participants, in order to
establish a reference range for use in clinical practice. The objectives of this study were to
measure the elasticity of the rotator cuff and biceps tendons (in kilopascals), using shear
wave ultrasound elastography and to establish a shear wave ultrasound elastographic
reference range of the rotator cuff and biceps tendons for use in clinical practice.
Methods: This quantitative study included 260 asymptomatic participants aged between 21
and 45 years (mean age 34.52±7.75 years). The demographic data incorporated participants’
age, gender, race, weight, height, daily lifestyle activities, body mass index and medical
history. Data was collected using a demographic questionnaire, B-Mode ultrasound and shear
wave ultrasound elastography, using the GE Logiq E 9 equipment. The proximal, middle and
distal sites of the biceps, subscapularis, and supraspinatus and infraspinatus tendons were
imaged in both longitudinal and axial planes. The teres minor tendon was imaged in a single
sagittal and axial plane.
Results: The reference ranges of the rotator cuff and biceps tendons have been evaluated by
finding 95% confidence intervals for the mean elasticity for each of the tendons. A 95%
confidence interval provides a lower and upper limit into which 95% of tendon measurements
would be expected to fall. The reference ranges for the mean tendon elasticity for the tendons
were as follows:
For the biceps tendon in sagittal and axial planes, the reference ranges are 102.52-108.34 kPa
and 96.44-101.08 kPa respectively. For the subscapularis tendon in sagittal and axial planes,
the reference ranges are 102.84-110.60 kPa and 110.60 kPa-108.02 kPa respectively. The
supraspinatus tendon in sagittal and axial planes have reference ranges 106.83-114.54 kPa
and 102.29-109.59 kPa, respectively. The infraspinatus tendon in sagittal and axial planes have reference ranges 102.39-111.87 kPa and 99.61-107.77 kPa respectively. The reference
ranges for teres minor tendon in sagittal and axial planes are 96.90-101.20 kPa and 96.68-
101.09 kPa respectively.
There was a statistically significant difference in the reference values observed between
males and females for the proximal, middle and distal sites of the biceps tendon in the sagittal
plane (p<0.05). The reference values ranged from 101.93±18.84 kPa-104.09±16.86 kPa (in
females) and 109.40±18.15 kPa-109.41±19.07 kPa (in males). A statistically significant
difference was also noted in the teres minor tendon in the sagittal and axial planes (p<0.05).
The reference values ranged from 96.71±16.49 kPa (in females)-102.74±18.76 kPa (in males)
in the sagittal plane and 97.03±18.29kPa (in females)-101.79±17.39 kPa (in males) in the
axial plane. Conclusion: This study provided a non-invasive estimate of the elasticity of the rotator cuff
and biceps tendons in kPa, using shear wave ultrasound elastography (SWUE). The results of
our study have the potential to complement B-Mode ultrasound in the diagnosis, treatment
and follow up of rotator cuff and biceps tendon pathology.
Description: 
A dissertation submitted to the Faculty of Health Sciences in full compliance for the requirement for the Master’s Degree in Technology: Radiography at Durban University of Technology, 2020.
URI: https://hdl.handle.net/10321/3848
DOI: https://doi.org/10.51415/10321/3848
Appears in Collections:Theses and dissertations (Health Sciences)

Files in This Item:
File Description SizeFormat
Ramdev_H_2019.pdfthesis4.26 MBAdobe PDFView/Open
Show full item record

Page view(s)

237
checked on Dec 22, 2024

Download(s)

274
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.