Abstract: 
The development of an effective technique for detecting anti-asthma drugs with adverse effects
in the human body at high dosages remains a serious challenge. For this purpose, herein, we
report a novel electrochemical detection method based on nanocomposite modified glassy
carbon electrode (GCE) nano-sensors. Cobalt ferrite (CoFe2O4), titanium oxide (TiO2) and zinc
oxide (ZnO) nanoparticles (ZnONPs) were synthesized as well as their respective
nanocomposites (CoFe2O4-MWCNTs-Lipase, TiO2-MWCNTs-IL, ZnONPs-MWCNTsCytochrome c and MWCNTs-Ionic liquid-L-lysine) were successfully prepared. Subsequently,
their surface morphology, crystal structure, functional groups, thermal stability, surface area as
well as pore size distribution of the synthesized nanoparticles and the nanocomposites aspects
were analysed. The characterization analyses were undertaken using scanning electron
microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD),
Brunauer-Emmett Teller (BET) adsorption analyses, thermal gravimetric analysis (TGA) and
Fourier-transform infrared spectroscopy (FTIR). In addition, electrochemical characterization
of the fabricated electrodes were examined using electrochemical impedance spectroscopy
(EIS) in order to ensure the material’s suitability in electro-catalytic sensing by investigating
the electron transfer kinetics of the redox probe at the modified electrode-solution interface.
The fabricated nanocomposite based sensors; ZnONPs-MWCNTs-Cyt c-GCE, CoFe2O4-
MWCNTs-Lipase-GCE, MWCNTs-IL-L-lysine-GCE and TiO2-MWCNTs-IL-GCE were
tested for electrochemical determination of theophylline, salbutamol, prednisolone and
terbutaline, respectively, using cyclic voltammetry (CV) and differential pulse voltammetry
(DPV). The effect of varying scan rates, pH of the supporting electrolyte and accumulation
time on the peak potential position and peak-currents, were studied with each electrode, and
the optimum working parameters were selected. The ZnONPs-MWCNTs-Cyt c-GCE,
CoFe2O4-MWCNTs-Lipase-GCE, MWCNTs-IL-L-lysine-GCE and TiO2-MWCNTs-IL-GCE
sensors were found to exhibit excellent electro-catalytic activity towards theophylline,
salbutamol, prednisolone and terbutaline. The synergy between these nanocomposite materials
increased the electrochemical activity, the electron transfer rate and the electrode surface area,
leading to high peak-current response for the determination of each drug.
ZnONPs-MWCNTs-Cyt c-GCE sensor presented acceptable long-term stability, good
reproducibility and repeatability. The limit of detection (LOD = 0.0012 µM) obtained was much lower than most of the given literature studies. Similarly, the CoFe2O4-MWCNTs-Lipase
nanocomposite modified GCE for salbutamol (SAL) exhibited excellent stability,
reproducibility and sensitivity with lowest detection limit (0.0240 µM) and limit of
quantification (LOQ) of 0.0120 µM, over the concentration range of 0.05- 3.9 µM. In addition,
the MWCNTs-IL-L-lysine-GCE exhibited outstanding electro-catalytic activity including
excellent reproducibility, with LOD and LOQ of 0.0214 μM and 0.3016 μM, respectively, for
prednisolone (PDN) detection. Moreover, at optimized electrochemical experimental
conditions, the electrochemical performance of the constructed TiO2-MWCNTs-IL-GCE
sensor for determination of terbutaline (TBS) was also evaluated. Stability, reproducibility as
well as the detection limits were determined. A wide linear range of 0.5 µM to 3.0 µM as well
as LOD and LOQ of 0.0162 µM and 0.2140 µM, respectively, were obtained and the results
were compared with similarly reported electrodes for terbutaline detection. The selectivity of
each sensor was also evaluated in presence of common interferences.
There was no significant interference on the electrochemical peak-current response and peak
position of each target analyte. The practical applicability of each fabricated sensor was
investigated by the DPV method with respect to the detection of the four drugs under study in
commercial pharmaceutical samples. In all cases, the sensors showed good percentage recovery
performance in real dosage samples. From the experimental results, it is evident that the
fabricated nanocomposite based sensors are ultra-sensitive for selective detection of the
investigated four drugs in pharmaceutical formulations and other sample matrices.
Description: 
Submitted in fulfilment of the requirements for the Degree of Master of Applied Science in Chemistry, Durban University of Technology, 2022.
URI: https://hdl.handle.net/10321/4121
DOI: https://doi.org/10.51415/10321/4121
Appears in Collections:Theses and dissertations (Applied Sciences)

Files in This Item:
File Description SizeFormat
Kilele_CJ_2022.pdfThesis12.65 MBAdobe PDFView/Open
Show full item record

Page view(s)

290
checked on Nov 20, 2024

Download(s)

78
checked on Nov 20, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.