Please use this identifier to cite or link to this item:
https://hdl.handle.net/10321/123
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Govender, Yoguvathie | en_US |
dc.date.accessioned | 2007-10-23T10:21:31Z | |
dc.date.available | 2007-10-23T10:21:31Z | |
dc.date.issued | 2007 | - |
dc.identifier.other | 307242 | - |
dc.identifier.uri | http://hdl.handle.net/10321/123 | - |
dc.description | Submitted in fulfillment of Masters in Radiography, Durban University of Technology, Durban, South Africa, 2007. | en_US |
dc.description.abstract | Aim/research questions The aim of the study was to evaluate CT-based treatment planning versus digitised image planning (standard planning technique) for carcinoma of the breast, using the four-field breast technique, in terms of the depth of supraclavicular and axillary nodes, the variability of the breast tissue and the dose inhomogeneity at the matchline. The variability of the depth of supraclavicular and axillary nodes has not been documented in any local or national studies. When simulating patients for treatment, it is evident that the anatomical variability of patient chest wall thickness, shape and size is a contributing factor towards the final treatment plan and dose distribution achieved. Therefore knowing the correct depth of the nodes and being able to clearly demarcate the breast tissue should result in a favourable dose administration. The following questions were addressed: What is the dose to the supraclavicular nodes from both plans? What is the dose to the axillary nodes from both plans? How do the plans differ in terms of dose coverage to the supraclavicular and axillary nodes? What is the relationship between the depth of the supraclavicular nodes and the patient separation? ii What is the relationship between the depth of the axillary nodes and the patient separation? Does the target volume receive adequate dose coverage from the plans? How is dose to the heart volume affected by target coverage on both plans? How is dose to the lung volume affected by target coverage on both plans? What is the dose variability along the matchline? Are the plans over dosing? Are the plans under dosing? | en_US |
dc.language.iso | en | en_US |
dc.subject | Tomography | en_US |
dc.subject.lcsh | Radiography, Medical | en_US |
dc.subject.lcsh | Cross-sectional imaging | en_US |
dc.subject.lcsh | Radiography--Dissertations, Academic | en_US |
dc.subject.lcsh | Breast--Tomography | en_US |
dc.subject.lcsh | Cancer--Tomography | en_US |
dc.title | An evaluation of computerised tomography (CT) based treatment planning versus digitised image planning (standard planning technique) for carcinoma of the breast, using the four field breast technique | en_US |
dc.type | Thesis | en_US |
dc.description.level | M | en_US |
dc.identifier.doi | https://doi.org/10.51415/10321/123 | - |
local.sdg | SDG03 | - |
item.openairetype | Thesis | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
Appears in Collections: | Theses and dissertations (Health Sciences) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Govender_2007.pdf | 5.57 MB | Adobe PDF | View/Open |
Page view(s) 50
1,043
checked on Dec 22, 2024
Download(s) 50
662
checked on Dec 22, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.